Crestron
e-control Vote SW-VOTE
65
••
Operations
Installation & Reference Guide — DOC. 5822
10
Clear a queue
To clear an individual queue, pulse one of the
ClearQueue
q
signals (typically joined
to a
Clear This Queue
button positioned near each queue).
Note that queues can be configured to automatically clear whenever a seat in the first
queue is recognized to speak. (See “
Auto-clear
,” page 43.)
11
Clear queue set
To clear all the queues in the queue set at once, pulse the
ClearQueueSet
signal
(typcially tied, through an “Are you sure?” dialog, to a
Clear All Queues
button).
12
Save queue set
To save the queue set, proceed to the Save Page and pulse one of the
Save
signals.
13
Clear all “save files”
The Save Page also features a
Clear ALL Queue Sets
button which is joined directly
to the
ClearFiles
signal.
14
Disable
The signal block is typically disabled upon exiting out of the Load or Save pages.
This is not mandatory. However, be aware that if the signal block is not disabled,
seats can continue to “buzz in.” With the signal block disabled, all seat request
button feedbacks go dark and will remain unresponsive until the signal block is again
enabled.