SPECIFICATION AND ENGINEERING DRAWINGS
STANDARD SPECIFICATIONS FOR CREST
ULTRASONIC OPTIMUM JUNIOR CONSOLES
AND RECIRCULATING HOT AIR DRYER
MODELS: OPTIMUM JUNIOR 1014 (OJ1014)
OPTIMUM JUNIOR 1218 (OJ1218)
OPTIMUM JUNIOR 1826 (OJ1826)
OPTIMUM JUNIOR 2424 (OJ2424)
OJ1014 OJ1218 OJ1826 OJ2424
Station 1:
Ultrasonic Heated Wash Tank
Ultrasonic Transducers (Watts)
Generators (Watts)
Heat (Watts)
Recirculation with 10 micron filter
Sparged Overflow
500
500
1000
YES
YES
1000
1000
2000
YES
YES
1500
1500
4000
YES
YES
2000
2000
6000
YES
YES
Station 2:
First Stage of Reverse Cascade Rinse
Ultrasonic Transducers (Watts)
Generators (Watts)
Heat (Watts)
500
500
1000
1000
1000
2000
1500
1500
4000
2000
2000
6000
Station 3:
Second Stage of Reverse Cascade Rinse
Heat (Watts)
Water Fill Sparger
1000
YES
2000
YES
4000
YES
6000
YES
Station 4:
Recirculating Hot Air Dryer Module
Heat (Watts)
1000 CFM Blower
Overtemperature Protection
Manual Sliding Cover
Auto Sliding Cover
3750
YES
YES
YES
OPTIONAL
3750
YES
YES
YES
OPTIONAL
5000
YES
YES
YES
OPTIONAL
7500
YES
YES
YES
OPTIONAL
Dimensions
Tanks: left to right (inches)
front to back (inches)
liquid depth (inches)
10
14
10
12
18
10
18
26
14
24
24
16
Footprint:
Wash/Rinse Console:
left to right (inches)
- without loading table
- with loading table
front to back (inches)
height (inches)
52
52
26
40
59
59
30
40
76
83
38
40
101
112
36
40