1019068-C
Page 15
47
INSTALLATION
(CDV255DPPD and CDV305DPPD)
TH
TP
THTP
ADJ
PIL
O
T
IN
green
wire
orange
wire
black
wire
STEP 5-A.
Connecting the PilotPro Wires
Find the three connection terminals at the
base of the heater IID Valve (
34
).
Find the green,
orange and black
wires that are
together on one
end of the Wiring
Harness (
57
).
- Connect Orange THTP wire to the THTP
terminal of the valve.
- Connect Black TP wire to the TP terminal of valve.
- Connect Green TH wire to TH terminal of
the valve.
NOTE: Ensure that all of the
connections are tightened firmly.
34
57
STEP 5-B.
On the inside of the CDV, locate the Flame
Sensor (
46
) and Ingitor (
32
).
Plug the Flame Sensor
(
46
) into one end of
the Flame Sensor
Wire (
47
).
Plug the Orange
Ignitor Wire (
33
) into
the Ignitor (
32
).
32
46
47
33
33