− 3 −

Introduction

 Safe Operation

In order to use the Gas Detector safely, be sure to observe the following items.

*Special Instruction and Warning :

Use Panasonic LR6XJK, Toshiba LR6, or Duracell MN1500 batteries.  Use of any other 

manufacuturer or type will violate intrinsic safety requirement.  Remove and replace the batteries 

only in areas known to be non-hazardous.  

1. Introduction (continued from previous page)

DANGER

  If the gas alarm turns ON, immediately take all necessary measures to 

prevent explosion accidents.

WARNING

  Be sure to turn ON the Gas Detector in clean air. Zero calibration is 

done automatically. Therefore, the wrong gas concentration will be 

displayed if zero calibration is done in a gas atmosphere.

  Do not close the suction port or exhaust port, or no gas detection will be 

possible.

  Use the filter element in a clean state. Normal detection cannot be 

performed if the filter element is dirty or moisture adheres to the filter 

element.

CAUTION

  Remove the batteries and store the Gas Detector if it is not to be used for a 

long time.

  The Gas Detector has an explosion-proof construction.  Do not disassemble 

or modify the Gas Detector or change the structure or electric circuits of 

the Gas Detector.  Otherwise, the explosion-proof performance of the Gas 

Detector will be damaged.

  Do not leave the Gas Detector in high-temperature or highly humid places, 

or the performance of the Gas Detector may be adversely affected.

  Keep the Gas Detector away from radical temperature or humidity changes, 

walkie-talkie, mobile phone, or its performance may be adversely affected.

  Keep the Gas Detector away from great atmospheric pressure changes, 

or the performance of the sensor may be adversely affected or the sensor 

may be damaged.

  Do not drop, hit, or apply a strong mechanical shock to the Gas Detector, or 

its performance may be adversely affected.

  The Gas Detector is not drip-proof but the leather case protects the Gas 

Detector from water drips. Keep the Gas Detector away from water drips 

as much as possible.

  Keep the Gas Detector away from places close to where silicone sealing 

materials are being used or silicon gas atmospheres, or its performance 

may be damaged.

  Do not let the Gas Detector draw in water.

  Do not use any batteries other than the specified one. otherwise it would 

damage the explosion-proof performance.

Содержание XP-3110

Страница 1: ...listed on the left Please keep this instruction manual available for quick reference when needed Before use carefully read this instruction manual and fully understand the content XP 3110 Combustible...

Страница 2: ...arm Buzzer Silence Settings 13 Changing the Sample Gas 14 Logging 15 Data Logger Communications Screen 16 Time Settings 17 4 Error Message Malfunction Alarm 18 5 Replacement of Consumable Parts 19 Fil...

Страница 3: ...eration has not been confirmed in other OS versions Hard disk Free space of 6 Mbytes or more CD ROM drive A CD ROM drive capable of reading CD R data The software is provided in a CD R disc USB port A...

Страница 4: ...g the Gas Detector to wear antistatic clothing and electrically conductive shoes antistatic work shoes The floor should also be electrically conductive with an electrical leakage resistance of 10 M or...

Страница 5: ...has an explosion proof construction Do not disassemble or modify the Gas Detector or change the structure or electric circuits of the Gas Detector Otherwise the explosion proof performance of the Gas...

Страница 6: ...ampling pipe connection port Connects to the gas sampling hose 3 Exhaust port Exhausts sampled gas 4 Buzzer opening Sounds a buzzer 5 Gas type seal Displays the model number and the types of detectabl...

Страница 7: ...range of the bar graph 10 LCD sub screen Displays gas concentration and messages J Indicates time K Displays a gas number confi rmed if the number of detectable combustible gases is two or more 11 Co...

Страница 8: ...k pocket Used to hold the sampling hose or provided filter No Name Function 1 Gas sampling hose Leads gas to the Gas Detector 1 m long 2 Coupler Connects to the Gas Detector 3 Drain filter DF 4 Preven...

Страница 9: ...ntration screen will be displayed WARNING Be sure to place the connected gas sampling hose in clean air when turning ON the Gas Detector Zero calibration is done automatically The wrong gas concentrat...

Страница 10: ...ressing the BZ STOP switch The screen will return to the clock display in approximately three seconds To change the sample gas refer to page 14 The gas number however cannot be confirmed during a gas...

Страница 11: ...sure to conduct zero adjustment or the precise measurement of gas may not be possible Range To change the bar graph range press the POWER switch while the gas concentration screen is displayed The ra...

Страница 12: ...oncentration reaches the alarm level again the gas alarm buzzer will sound again If the pointer scales out when detecting high concentration gas OL will be displayed High concentration gas may have an...

Страница 13: ...able gas selection Allows detectable gas selection if the number of detectable combustible gases is two or more P 14 4 LCD selection This detector can not be set 5 Execution and completion of logging...

Страница 14: ...lumination to flashing 3 Press the LIGHT switch to change from OFF to ON 4 Press the MENU switch to enter the settings The ON indication will change from flashing to steady illumination and 1PE will c...

Страница 15: ...dy illumination to flashing 3 Press the BZ STOP switch and change ON to OFF will change to 4 Press the MENU switch to enter the settings The OFF indication will then change from flashing to steady ill...

Страница 16: ...ing and 1 01 will start flashing 3 Press the LIGHT switch to select the gas number 4 Press the MENU switch to enter the settings The 1 02 indication will then change from flashing to steady illuminati...

Страница 17: ...d OFF will change from steady illumination to flashing 3 Press the LIGHT switch to change OFF to ON 4 Press the MENU switch to enter the settings The ON indication will then change from flashing to st...

Страница 18: ...op flashing and ON will start flashing Data logger communication with the PC will then be possible Operate the PC for data logger communication 4 When communication is finished press the POWER switch...

Страница 19: ...the setting and press the MENU switch to enter the value 5 Date Setting When the MENU switch is pressed CL3 will change from flashing to steady illumination and the date value will change from steady...

Страница 20: ...the battery voltage drops and the remaining battery level is low The Gas Detector will not work when the battery voltage is low Replace the batteries see pages 20 Use approved batteries Duracell MN150...

Страница 21: ...2 Use a small flat blade screwdriver to remove the O ring in the filter case 3 Replace the FE 2 Filter Element with a new one and reassemble the parts WARNING If water is drawn into the inside of the...

Страница 22: ...into the case part No 3620584053 and zip it shut before entering the hazardous location WARNING Use Panasonic LR6XJK Toshiba LR6 or Duracell MN1500 batteries Use of any other manufacturer or type wil...

Страница 23: ...in filter clean the inside of the drain filter and 1 m long gas sampling hose and replace the filter element with a new one see page 19 Remaining battery level If the remaining battery level is low re...

Страница 24: ...rned on even if you press the POWER switch T h e p o l a r i t y i s incorrect Install batteries again in the correct polarity Battery r e p l a c e m e n t P20 Battery life Replace the batteries The...

Страница 25: ...mos s sole option replacement or repair of such non conforming product or refund of the original purchase price of the non conforming product In no event will New Cosmos be liable for any other specia...

Страница 26: ...lkaline batteries Approx 30 hrs Alkaline batteries Approx 20 hrs Approx 15 hrs Methane specifications At an ambient temperature of 20 C with the alarm backlight and data logging function turned OFF Op...

Страница 27: ...Rev 2009 12 08 UL 60079 11 5th Ed Rev 2011 05 05 UL 60079 1 6th Ed Rev 2009 04 10 EN 60079 0 2012 EN 60079 0 2012 EN 60079 11 2012 EN 60079 1 2007 IEC 60079 0 6th Ed Corr 1 IEC 60079 0 6th Ed Corr 1...

Страница 28: ...d the resistance of the platinum filament will decrease This resistance change is output as a voltage deviation change of the bridge circuit The sensor is very sensitive to low concentrations making i...

Страница 29: ...sphere are to be placed in an enclosure which can withstand the pressure developed during internal explosion of an explosive mixture and which prevents the transmission of the explosion to the explosi...