− 24 −
Specifications
■
Gas Detector
9. Specifications
Product
Combustible Gas Detector
High-concentration Gas Detector High-sensitivity Gas Detector
Model
XP-3110
XP-3140
XP-3160
Detectable gases
C o m b u s t i b l e g a s a n d
combustible solvent steam
Manufacturing gas, natural
gas, methane, hydrogen,
helium, carbon dioxide, argon,
liquefied petroleum gas,
butane, and butane air (6A)
C o m b u s t i b l e g a s a n d
combustible solvent steam
Detection principle
Catalytic combustion type
Thermal conductivity type
Catalytic combustion type
Gas sampling method
Automatic suction type
Detection range
0% to 100% (LEL)
0vol% to 100vol%
0 to 5,000 ppm
0vol% to 1vol%
Indication accuracy (see
note 1)
±5% of FS
H range: ±5% of FS
L range: ±10% of FS
H range: ±5% of FS
L range: ±10% of FS
Alarm set value
20% (LEL)
50vol%
250 ppm/0.05vol%
Gas alarm method
Buzzer sounds, red lamp flashes, and LCD flashes
Power supply
Four AA alkaline batteries (LR6) Use DURACELL MN1500 batteries, Toshiba LR6 or Panasonic LR6XJK.
Continuous operating
hours (see 2)
Alkaline batteries: Approx. 20
hrs.
Approx. 15 hrs. (Methane
specifications)
Alkaline batteries: Approx.
30 hrs.
Alkaline batteries: Approx.
20 hrs.
Approx. 15 hrs. (Methane
specifications)
(At an ambient temperature of 20°C with the alarm, backlight, and data logging function turned OFF.)
Operating temperature
and humidity range
0°C to 40°C and 95% max. (with no condensation)
Explosion proof
DEMKO 12 ATEX 1014729X
II 2 G Ex d ib IIB T4 Gb
IECEx UL 13.0012X Ex d ib IIB T4 Gb
Other major alarms
Remaining battery level, sensor error, and flow rate drop
Main functions
• Zero adjustment
Sensor zero adjustment is possible at the time of starting the Gas Detector and at any time while the Gas
Detector is on.
• Peak hold
A peak display of gas concentration is possible.
• Buzzer stop
A switch to stop a sounding buzzer.
• Backlight
A switch to turn the backlight ON.
• Data logging
Size (excluding projections) Approx. W 82 x H 162 x D 36 mm
Weight
Approx. 605 g (including alkaline batteries)
Accessories
Leather case, Shoulder belt, Four AA alkaline batteries, Gas sampling hose (1 m), Spare filter elements (two elements)
Optional item
Gas sampling hose, Mixer, Log Data Collection Set
*1. Indication accuracy: Under identical measurement conditions.
*2. The operating time of the batteries depends on factors such as environmental conditions, operating conditions, the storage time, and the
manufacturer.