52
COSMOGAS
AGUAPLUS
14 - USE
Lock-
up
Lock-up description
Checks
Solutions
Loc 20
Flame lost three times
Make sure: that the ionisation current is at a value
higher than 4 (follow the procedure in section 15.12)
If the ionisation current is not over 4, you must check the
CO2 (follow section 13.8) and restore the proper value.
Check the ionisation glow plug and, if necessary, replace
it. Make sure the ionisation current electrical circuit cables
are intact.
Make sure: that the flue exhaust is appropriately
protected from obstructions caused by gusts of wind
If the flue exhaust is positioned on a vertical wall,
it must be protected by a windproof grid. If the flue
exhaust is positioned on the roof, make sure it is not
in a reflux area and that the windproof chimney, if any,
is actually efficient.
Loc 21
Software error inside
command board
Replace the command and control board
Loc 22
Software error inside
command board
Replace the command and control board
Loc 23
Software error inside
command board
Replace the command and control board
Loc 24
Software error inside
command board
Replace the command and control board
Loc 25
(*)
Gas valve circuit
Check whether the heating supply safety thermostat
has tripped;
WARNING !!! If the flue exhaust temperature
safety fuse trips, you must contact the appliance
manufacturer to avoid serious damage to the
exchanger.
Check whether the flue exhaust temperature safety
fuse has tripped;
Loc 26
Software error inside
command board
Replace the command and control board
Loc 27
Flame with gas valve
closed
Replace the gas valve
Loc 28
Flame with gas valve
closed
Replace the gas valve
Loc 29
(*)
Flue exhaust pressure
switch circuit or external
safety devices
Check the connection to the external safety device;
Check the external safety devices connected to
terminals 103 and 104.
Check whether the flue exhaust differential pressure
switch has tripped;
Check the pressure switch against flue exhaust
obstruction and replace if necessary.
Check whether the flue exhaust is obstructed;
Remove any obstructions from the flue exhaust.
Loc 30
Software error inside
command board
Check the pressure switch against flue exhaust
obstruction;
Check.
Loc 31
Flame lost three times
Check the detection electrode;
Try replacing the detection electrode.
Make sure that the flue exhaust is appropriately
protected from obstructions caused by gusts of wind.
Check for and, if necessary, remove any obstructions
from the air intake and flue exhaust ducts;
Check for any flue exhaust recirculation
Find the cause of the flue exhaust recirculation
Loc 32
Software error inside
command board
Replace the command and control board
Loc 33
Software error inside
command board
Replace the command and control board
Loc 34
Software error inside
command board
Replace the command and control board
Loc 35
Software error inside
command board
Replace the command and control board
Loc 36
Software error inside
command board
Replace the command and control board
Loc 37
Software error inside
command board
Replace the command and control board
Loc 38
The flue exhaust sensor
temperature does not
rise when the burner
ignites
Make sure the flue gas sensor meets the require
-
ment in section 15.14.
If the flue gas sensor does not meet section 15.14, it
must be replaced.
Make sure that the flue gas sensor (parameter 1006)
increases the temperature when the burner ignites.
If the temperature does not rise, replace the flue gas
temperature sensor or the command and control board.