Description:
Manual L4 ES HP; L4 ES HP W
Document Number:
1004289
Created By:
MSHN
Revision Approval Date:
2019-06-28
Revision:
A
© Corroventa Avfuktning AB
15 (42)
Drying framed flooring and beams
For framed flooring and beams with easy-to-dry insulation, for example, glass wool, L4 ES can be used
with a high-pressure fan such as HP2000 according to the schematic diagram below. Remember that the
capacity of this fan far exceeds that of the dehumidifier and therefore allow the fan to "draw the bad
air". The diagram below shows this by the dry air hose from the dehumidifier to the right not being
connected directly to the fan, but placed next to it instead. In this way, the fan can draw enough air
without drawing excess air through the dehumidifier affecting its function and efficiency
.
D
RYING BEAMS USING A FAN
.
N
OTE THAT THE DEHUMIDIFIER TO THE RIGHT IS NOT
DIRECTLY CONNECTED TO THE FAN
.
T
HE DRY AIR HOSE IS ONLY PLACED CLOSE TO THE
FAN
.