Description:
Manual L4 ES HP; L4 ES HP W
Document Number:
1004289
Created By:
MSHN
Revision Approval Date:
2019-06-28
Revision:
A
© Corroventa Avfuktning AB
22 (42)
and RH sensor. If the machine is not already connected to
the network, the machine asks whether to create a
network.
If there are several sensors in the network and if the <All<
option has been selected (instead of a single sensor, e.g.
RHT61) the machine works on the "worst case scenario"
and runs for as long as any of the sensors detects that the
humidity is above the setpoint.
If the machine selects a mode other than MAN, the user
will note that the setpoint can be set.
When the setpoint has been reached, drying stops
automatically. If the humidity later rises above the
setpoint again, drying resumes automatically.
Hysteresis
When one of control modes; RH, DP or X is selected, a
symbol and a hysteresis value appears to the right of the
display.
The symbol shows the setpoint value's position in the
operation range as below.
↕
- centre
↓
- bottom
↑
- top
Fan mode
The fan mode determines whether the fan in the
dehumidifier is to work continuously or only for as long as
drying is required.
If continuous fan is selected, the word Cont appears in
the lower right-hand corner in standard view.
For optimal drying effect, continuous fan operation
should be used as far as is possible to keep the air
moving.