USER GUIDE 

9651 

HARDWIRED CONTROL 

PANELS 

Содержание Menvier 9651

Страница 1: ...USER GUIDE 9651 HARDWIRED CONTROL PANELS...

Страница 2: ...e 16 3 After an Alarm 17 Fire Alarm 17 Disarming the System 17 Resetting the System 17 Customer Reset 18 Remote Reset 18 4 Special Functions 19 Introduction 19 Omitting Zones 19 Access Codes 20 Duress...

Страница 3: ...le system protecting all of the premises covered by the alarm system Levels B C and D set part of the system protecting part of the premises while the rest is in use The system raises an alarm when a...

Страница 4: ...Line Fault Glows steadily if the connected telephone line is not working correctly s Service Glows steadily if the system needs attention from an Engineer or Installer a Power Glows steadily when mai...

Страница 5: ...make a mistake when entering access codes Y Enter programming and setting unsetting commands About This Guide The rest of this guide tells you how to use the system in more detail 2 Everyday Operatio...

Страница 6: ...these routes you may cause a false alarm How Do I Know if the System is Working The a lamp always glows when the mains power is present If the a lamp flashes slowly then mains power is off and the sys...

Страница 7: ...ypads or internal sounder then something is triggering one of the detectors See also If The System Will Not Set on p12 4 Leave via the designated exit route Close the final door At the end of the exit...

Страница 8: ...remises by the final door Pressing the button completes setting the system 1 Close all doors and windows 2 Key in your access code or present a tag at the keypad 3 Press the appropriate Level key The...

Страница 9: ...me Levels on your system may be programmed for Silent Set When setting these Levels the system does not give any tones from the keypads or internal sounder 4 Leave via the designated exit route and if...

Страница 10: ...s are closed Some types of keyswitch do not have lamps Off Armed Ready Full Part Off Armed Ready Full Part Off Armed Ready Full OR Part 2 Either turn the keyswitch to Full to set Level A Or turn the k...

Страница 11: ...y in your access code or present a tag at the keypad 3 Press the appropriate Level key The keypad starts the continuous exit tone You may hear an interrupted tone if the final exit door is open Exit t...

Страница 12: ...t disappears the control unit switches the s lamp off The keypad sounds a soft intermittent beep to draw your attention This attention tone continues even if the s lamp goes off To indicate the nature...

Страница 13: ...lamps will continue to glow for as long as the fault is present If the system detects that the fault has been rectified then the s and f lamps go off If the s and f lamps remain glowing for more than...

Страница 14: ...ough for you to enter by the designated entry route get to the keypad and unset the system The entry time starts when you open the designated entry door During the entry time the keypads give a gallop...

Страница 15: ...he entry timer and the keypads give the entry tone Entry tone 2 Key in your access code or present a tag The entry tone stops and the system gives a double beep The system is now unset beep beep If Yo...

Страница 16: ...l Assistance Alarm On a keypad press 4 6 together To start a Fire Alarm On a keypad press 7 9 together Duress Code There may be a time when an intruder forces you to unset your alarm system There is a...

Страница 17: ...he System If the system is full set then 1 Go to the keypad via the entry route 2 Key in your access code or present a tag The sounders go quiet and the system gives a double beep to show that it is u...

Страница 18: ...before read the instructions through before starting 1 Key in your access code or present a tag The display shows 2 Press Y The display shows a four digit Reset Code 3 Write down the four digit Reset...

Страница 19: ...sent a tag and then press a number key The rest of this section describes each function in turn Omitting Zones Your system may be programmed so that you can omit individual detectors Ask your Installe...

Страница 20: ...ow User 01 is the only access code that can change other access codes User 02 default access code is X 002 User 03 is X 003 and so on up to User 16 X 016 However the default access codes for these use...

Страница 21: ...press Y in step 3 above the display shows the current user name with a flashing cursor under the first letter Enter letters from the keypad one at a time by pressing a number key repeatedly until the...

Страница 22: ...gn a user a tag an access code or both You cannot assign a tag to the Master User user 01 or the Engineer user 00 This means that you can assign up to 15 tags per system one for each of users 02 to 16...

Страница 23: ...s as necessary To Delete a Tag Note If you delete a tag you also delete the user s access code 1 Key in User 01 access code while the system is unset The display shows 2 Press 4 to select the change c...

Страница 24: ...iring tamper System Tamp Rst System tamper reset Lid Tamper Control unit lid opened Lid Tamper Rst Lid tamper reset Sounder Tamper Sounder lid opened Sounder Tamp Rst Sounder tamper reset Unn On Site...

Страница 25: ...ine restored Comms Fail The communicator failed to report AC Fail Mains failed AC Restore Mains restored Low Battery Standby battery is low Low Batt Rstr Standby battery restored Batt Missing 12V supp...

Страница 26: ...Key in User 01 access code or present a tag 2 Press 6 The display shows the date 3 Key in two digits for the day followed by Y 4 Key two digits for the month 01 for January to 12 for December followe...

Страница 27: ...l your alarm company and ask them to check the system Note If your system is fitted with 24 hour or personal attack detectors you cannot walk test them If you wish to test them call your alarm company...

Страница 28: ...owed Chime 1 2 3 4 5 6 7 8 Bell Duration Engineer Reset Communicator Fitted Part Set A Exit Time Part Set A Entry Time Part Set B Exit Time Part Set B Entry Time Part Set C Exit Time Part Set C Entry...