6.2
Single line descriptions
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
x.01
Solutions Module ID
0 to 599
104
RO Uni
PT US
x.03
Speed feedback
±40,000.0 rpm
RO Bi
FI NC PT
x.04
Revolution counter
0 to 65,535 revolutions
RO Uni FI NC PT
x.05
Position
0 to 65,535 (1/2
16
ths of a
revolution)
RO Uni FI NC PT
x.07
Marker position reset
disable
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.08
Marker flag
OFF (0) or On (1)
OFF (0)
RW Bit
NC
x.10
Equivalent lines per
revolution
0 to 50,000
4,096
RW Uni
US
x.13*
Encoder supply voltage
0: 5V
1: 8V
2: 15V
0
RW Uni
US
x.15
Encoder type
Ab (0), Fd (1), Fr (2)
Ab (0)
RW Uni
US
x.16
Encoder termination
0 to 2
1
RW Bit
US
x.19
Feedback filter
0 to 5 (0 to 16 ms)
0
RW Uni
US
x.24*
Encoder simulation source
Pr
0.00
to Pr
21.51
0.00
RW Uni
PT US
x.25*
Encoder simulation ratio
numerator
0.0000 to 3.0000
0.2500
RW Uni
US
x.28*
Encoder simulation mode
0: Ab
1: Fd
2: Fr
3: Ab with marker lock
4 to 7: Fd with marker lock
0
RW Uni
US
x.29
Non-marker reset
revolution counter
0 to 65,535 revolutions
RO Uni
NC PT
x.30
Non-marker reset position
0 to 65,535 (1/2
16
ths of a
revolution)
RO Uni
NC PT
x.32
Marker revolution counter
0 to 65,535 revolutions
RO Uni
NC PT
x.33
Marker position
0 to 65,535 (1/2
16
ths of a
revolution)
RO Uni
NC PT
x.35
Freeze revolution counter
0 to 65,535 revolutions
RO Uni
NC PT
x.36
Freeze position
0 to 65,535 (1/2
16
ths of a
revolution)
RO Uni
NC PT
x.39
Freeze flag
OFF (0) or On (1)
OFF (0)
RW Bit
NC
x.45
Position feedback
initialised
OFF (0) or On (1)
RO Bit
NC PT
x.49
Lock position feedback
OFF (0) or On (1)
RW Bit
x.50
Solutions Module error
status
0 to 255
RO Uni
NC PT
RW
Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not cloned
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save
*Pr
x.13
, Pr
x.24
, Pr
x.25
and Pr
x.28
are only used when operating with a SM-Encoder
Output Plus module. These parameters are not used when operating with a SM-Encoder
Plus module
NOTE