36
SM-Encoder Plus & SM-Encoder Output Plus User Guide
www.controltechniques.com
Issue: 4
Any trip can be initiated by writing the relevant trip number to Pr
10.38
. If any trips
shown as user trips are initiated the trip string is "txxx", where xxx is the trip number.
Trips can be reset after 1.0s if the cause of the trip has been rectified.
A full list of drive trips can be found in the appropriate drive manual.
Table 7.1 Trip codes
Trip
Diagnosis
C.Optn
SMARTCARD trip: Solutions Modules fitted are different between source drive
and destination drive
180
Ensure correct Solutions Modules are fitted
Ensure Solutions Modules are in the same Solutions Module slot
Press the red
reset button
Enc1
Drive encoder trip: Encoder power supply overload
189
Check encoder power supply wiring and encoder current requirement
Maximum current = 200mA @ 15V or 300mA @ 8V and 5V
Enc2
Drive encoder trip: Wire break (Drive encoder terminals 1 & 2, 3 & 4, 5 & 6)
190
Check cable continuityCheck wiring of feedback signals is correct
Check encoder power supply is set correctly
Replace feedback device
If wire break detection on the main drive encoder input is not required, set Pr
3.40
= 0
to disable the Enc2 trip
PS.24V
24V internal power supply overload
9
The total user load of the drive and Solutions Modules has exceeded the internal 24V
power supply limit.
The user load consists of the drive’s digital outputs plus the SM-I/O Plus digital
outputs, or the drive’s main encoder supply plus the SM-Universal Encoder Plus and
SM-Encoder Output Plus encoder supplies.
•
Reduce load and reset
•
Provide an external 24V >50W power supply
•
Remove any Solutions Modules and reset
SLX.dF
Solutions Module slot X trip: Solutions Module type fitted in slot X changed
204,209,
214
Save parameters and reset
SLX.Er
Solutions Module slot X trip: Error detected with Solutions Module, where X is
the slot number
202
207
212
When the drive is reset this parameter is cleared for the relevant Solutions Module
SLX.HF
Solutions Module slot X trip: Solutions Module X hardware fault
200,205,
210
Ensure Solutions Module is fitted correctly
Return Solutions Module to supplier
Pr x.50 Fault description
0
No errors
1
Power supply overloaded
Содержание SM-Encoder Output Plus
Страница 42: ...0471 0026 04...