M’Ax Advanced User Guide
10
Issue Number: 4
www.controltechniques.com
0: Reference selection by terminal input
The reference selected depends on the state of bit parameter [1.42] to [1.44]. These bits are for control by digital inputs such that reference
can be selected by external control. If any of the bits are set, the appropriate reference is selected (indicated by parameter [1.49]). If more
than one bit is set the highest numbered will have priority.
X = 0 or 1 (don't care condition)
1 or 2: Analog Reference
The speed reference is selected from the standard (SL) or high precision (AN) analog voltage input.
3: Preset reference selected
The reference is one of the four preset speeds, refer to parameters [1.15] and [1.21] to [1.24] for further details.
4: Keypad reference selected
The drive is controlled via keypad (Parameter [1.17] or [0.34])
5: Pulse reference selected
F&D/quadrature reference selected.
Parameter [1.15] selects a preset speed reference as follows:
0 = Preset select by terminal input
1 = Preset 1 selected [1.21]
2 = Preset 2 selected [1.22]
3 = Preset 3 selected [1.23]
4 = Preset 4 selected [1.24]
0: Preset selection by terminal input
The preset selected depends on the state of bit parameter [1.45] to [1.46]. These bits are for control by digital inputs such that presets can be
selected by external control. The preset selected depends on the binary code generated by these bits as follows:
Version _AN - [0.34] or [1.17] indicates the value of the speed reference set by use of the keypad.
Version _SL - [0.34] or [1.17] is not used.
If this parameter is selected as the frequency reference (i.e. [1.49] = 4), it is adjusted by the 'Up' and 'Down' keys only when the display is in
the Status Mode. When the drive is not enabled view the keypad reference by looking at parameter [0.34] or [1.17] to ensure the correct value
is set before enabling the drive.
The value is saved on power down such that the keypad frequency reference does not have to be set up again on power up.
1.42 Preset-
reference
selected indicator
1.43 Keypad-
reference
selected indicator
1.44 Pulse-
reference
selected indicator
Reference
selected
1.49 Indication
parameter
0
0
0
Analog
1
1
0
0
Preset
3
x
1
0
Keypad
4
x
x
1
Pulse
5
1.15
Preset reference selector
ô
0 ~ 4
ð
0
RW
Uni
P
Parameter [1.45]
Parameter [1.46]
Preset selected [1.50]
0
0
1
1
0
2
0
1
3
1
1
4
1.17
Keypad reference
ô
± Pr 1.06
ð
rpm
RO
Bi
S
P
0.34
1.21
Preset reference 1
ô
± Pr 1.06
ð
1
rpm
RW
Bi
0.33
1.22
Preset reference 2
ô
± Pr 1.06
ð
10
rpm
RW
Bi
1.23
Preset reference 3
ô
± Pr 1.06
ð
100
rpm
RW
Bi
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...