M’Ax Advanced User Guide
54
Issue Number: 4
www.controltechniques.com
Parameter not used
Parameter not used.
This invert parameter is used to change the sense of terminal 5 on the Digital I/O port.
0 = Not inverted
1 = Inverted
This invert parameter is used to change the sense of terminal 4 on the Digital I/O port.
0 = Not inverted
1 = Inverted
This invert parameter is used to change the sense of terminal 3 on the Digital I/O port.
0 = Not inverted
1 = Inverted
This invert parameter is used to change the sense of terminal 2 on the Digital I/O port.
0 = Not inverted
1 = Inverted
This invert parameter is used to change the sense of terminal 8 and 10 on the MC/EIA485 port. Setting this parameter to a 1 causes the
output from the source parameter to be inverted.
0 = Not inverted
1 = Inverted
This parameter should be programmed with the source parameter for terminal 5 on the Digital I/O port. Only bit parameters can be
programmed into this parameter. If a non-valid parameter is programmed an output will assume the last valid state (i.e. the value of previously
programmed parameter). After modification of this parameter the source is only changed when a reset is performed or a power down and
back up again. Defaulted to drive running.
This parameter should be programmed with the source parameter for terminal 4 on the Digital I/O port. Only bit parameters can be
programmed into this parameter. If a non-valid parameter is programmed an output will drive current. After modification of this parameter the
source is only changed when a reset is performed or a power down and back up again. Defaulted to At zero speed.
8.59
Status line indicator
ô
0 ~ 1
ð
RO
Bit
8.60
Status line output enable
ô
0 ~ 1
ð
RO
Bit
8.61
Digital output 1 invert
ô
0 ~ 1
ð
0
RW
Bit
8.62
Digital output 2 invert
ô
0 ~ 1
ð
0
RW
Bit
8.63
Digital output 3 invert
ô
0 ~ 1
ð
0
RW
Bit
8.64
Digital output 4 invert
ô
0 ~ 1
ð
0
RW
Bit
8.65
Status relay invert
ô
0 ~ 1
ð
0
RW
Bit
8.71
Digital output 1 source selector (DRIVE RUNNING)
ô
0.00 ~ 20.50
ð
10.02
Menu.Par
RW
Uni
P
8.72
Digital output 2 source selector (AT ZERO SPEED)
ô
0.00 ~ 20.50
ð
10.03
Menu.Par
RW
Uni
P
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...