The drive will trip on I2t.AC if 10.58 > 100%, for the time specified in parameter 4.54 Motor Overload time limit. Refer to parameter 4.54.
The drive will trip on O.ht3 if 10.59 > 85
°
C.
This bit parameter is set to indicate that either the “SL.Er” or “dL.Er” trip condition has occurred.
10.58
Motor I
2
T accumulator
ô
0.0 ~ 100.0
ð
%
RO
Uni
P
0.40
10.59
SLM PCB temperature
ô
0 ~ 100
ð
°
C
RO
Uni
10.60
SLM technology fault warning
ô
0 ~ 1
ð
RO
Bit