Menu 10 Parameters - Status and Diagnostic Information,
Trip log, Braking control
The under-voltage protection [10.53] can only be disabled via a digital input.
Parameter
Range(
ô
)
Default(
ð
)
Type
10.01
Drive healthy indicator
0 ~ 1
RO
Bit
P
10.02
Drive running indicator
0 ~ 1
RO
Bit
P
10.03
At zero speed indicator
0 ~ 1
RO
Bit
P
10.05
Below set speed indicator
0 ~ 1
RO
Bit
P
10.06
At speed indicator
0 ~ 1
RO
Bit
P
10.07
Above set speed indicator
0 ~ 1
RO
Bit
P
10.11
Braking active indicator
0 ~ 1
RO
Bit
P
10.12
Braking-resistor overload alarm indicator
0 ~ 1
RO
Bit
P
10.15
AC supply loss indicator
0 ~ 1
RO
Bit
P
10.16
UV warning flag
0 ~ 1
RO
Bit
10.17 {0.39}
Motor [I2t] overload trip indicator
0 ~ 1
RO
Bit
P
10.18
Heatsink temperature alarm indicator
0 ~ 1
RO
Bit
P
10.19
Alarm indicator
0 ~ 1
RO
Bit
P
10.20 {0.44}
Last trip
RO
Txt
S
P
10.21
Second last trip
RO
Txt
S
P
10.22
Third last trip
RO
Txt
S
P
10.23
Fourth last trip
RO
Txt
S
P
10.24
Fifth last trip
RO
Txt
S
P
10.25
Sixth last trip
RO
Txt
S
P
10.33
Drive reset
0 ~ 1
RO
Bit
10.38
User-defined trips
0 ~ 255
0
RW
Uni
10.39 {0.42}
Internal braking-resistor overload accumulator
0 ~ 100.0%
RO
Uni
P
10.40
Status word
0 ~ 32767
RO
Uni
P
10.41
Trip-0 time (years, days)
0.000 ~ 9.365 y.d
RO
Uni
P
10.42
Trip-0 time (hours, minutes)
00.00 ~ 23.59 h.m
RO
Uni
S
P
10.43
Trip-1 time (hours, minutes)
00.00 ~ 600.00 h.m
RO
Uni
S
P
10.44
Trip-2 time (hours, minutes)
00.00 ~ 600.00 h.m
RO
Uni
S
P
10.45
Trip-3 time (hours, minutes)
00.00 ~ 600.00 h.m
RO
Uni
S
P
10.46
Trip-4 time (hours, minutes)
00.00 ~ 600.00 h.m
RO
Uni
S
P
10.47
Trip-5 time (hours, minutes)
00.00 ~ 600.00 h.m
RO
Uni
S
P
10.52
SLM technology failure indicator
0 ~ 512
RO
Uni
P
10.53
Under-voltage protection disable
0 ~ 1
RO
Bit
P
10.54
AC-supply phase failure protection disable
0 ~ 1
0
RW
Bit
10.55
Internal braking-resistor protection disable
0 ~ 1
0
RW
Bit
10.56 {0.41}
Drive overload accumulator
0.0 ~ 100.0%
RO
Uni
P
10.57
Supply interlock
0 ~ 1
RO
Bit
P
10.58 {0.40}
Motor I
2
t accumulator
0.0 ~ 100.0%
RO
Uni
P
10.59
SLM PCB temperature
0 ~ 100
°
C
RO
Uni
P
10.60
SLM technology fault warning
0 ~ 1
RO
Bit
NOTE
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...