M’Ax Advanced User Guide
52
Issue Number: 4
www.controltechniques.com
This invert parameter is used to change the sense of terminal 6 on the Digital I/O port. Setting this parameter to 1 causes the input sense to
the destination parameter to be inverted.
0 = Not inverted
1 = Inverted
This invert parameter is used to change the sense of terminal 13 on the Digital I/O port. Setting this parameter to 1 causes the input sense to
the destination parameter to be inverted.
0 = Not inverted
1 = Inverted
This invert parameter is used to change the sense of terminal 12 on the Digital I/O port. Setting this parameter to 1 causes the input sense to
the destination parameter to be inverted.
0 = Not inverted
1 = Inverted
This word is used to determine the status of the digital I/O by reading one parameter. The bits in this word reflect the state of parameters 8.01
to 8.08 and parameters 8.51 to 8.60.
* Reserved for future development.
This parameter should be programmed with the destination parameter for terminal 10 on the Digital I/O port. Only bit parameters can be
programmed into this parameter. If a non-valid parameter is programmed the input is not routed anywhere. After modification of this
parameter the destination is only changed when a reset or power down and back up again. Defaulted to Run.
This parameter should be programmed with the destination parameter for terminal 9 on the Digital I/O port. Only bit parameters can be
programmed into this parameter. If a non-valid parameter is programmed the input is not routed anywhere. After modification of this
parameter the destination is only changed when a reset or power down and back up again. Defaulted to Reverse select.
This parameter should be programmed with the destination parameter for terminal 8 on the Digital I/O port. Only bit parameters can be
programmed into this parameter. If a non-valid parameter is programmed the input is not routed anywhere. After modification of this
parameter the destination is only changed when a reset or power down and back up again. Defaulted to Jog forward.
8.16
Digital Input 6 invert
ô
0 ~ 1
ð
RO
Bit
P
8.17
Digital Input 7 invert
ô
0 ~ 1
ð
RO
Bit
P
8.18
Digital Input 8 invert
ô
0 ~ 1
ð
RO
Bit
P
8.20
Digital input / output read word
ô
0 ~ 16384
ð
RO
Uni
P
Bit
Digital I/O
Parameter
Bit
Digital I/O
Parameter
0
Digital input 1
8.01
8
Digital Output 1
8.51
1
Digital input 2
8.02
9
Digital Output 2
8.52
2
Digital input 3
8.03
10
Digital Output 3
8.53
3
Digital input 4
8.04
11
Digital Output 4
8.54
4
Digital input 5
8.05
12
Status Line Input*
8.59
5
Digital input 6
8.06
13
Status Line Output*
8.60
6
Digital input 7
8.07
14
7
Digital input 8
8.08
15
8.21
Digital input 1 destination selector (RUN)
ô
0.00 ~ 20.50
ð
6.34
Menu.Par
RW
Uni
P
8.22
Digital input 2 destination selector (REVERSE SELECT)
ô
0.00 ~ 20.50
ð
6.33
Menu.Par
RW
Uni
P
8.23
Digital input 3 destination selector (JOG FORWARD)
ô
0.00 ~ 20.50
ð
6.31
Menu.Par
RW
Uni
P
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...