21
M’Ax Advanced User Guide
www.controltechniques.com
Issue Number: 4
Final speed demand at the input to the speed regulator formed by the sum of the ramp output and the hard speed reference (if the hard speed
reference is enabled). If the drive is disabled this parameter will show 0.0.
This is the speed feedback taken from the SLM encoder. This parameter shows the speed feedback used by the speed controller. This
includes quantisation ripple given by the counts per revolution (65535) and the sampling interval of 250
µ
s.
The value seen on the drive display is filtered so that it can be read by the user, however, the actual parameter held within the drive is not
filtered. If this parameter is routed to an analog output the ripple will be present. It should be noted that the quantisation of the speed feedback
does not affect the resolution or accuracy of the speed controller. Use parameter 3.64 for analog output purposes for fast responses.
If the speed feedback (parameter 3.02) is at or below the level defined by this parameter in either direction the Zero speed flag (parameter
10.03) is 1, otherwise the flag is 0.
Defines the lower threshold for at speed detection. Refer to parameter 3.09.
Defines the upper threshold for at speed detection. Refer to parameter 3.09.
Defines the speed above which the drive will trip due to overspeed.
When this parameter is set to a zero the limit is set by parameter 1.06 x 1.2.
3.09 = 0 reference window mode. The at speed band is from (reference - lower limit) to (ref upper limit). The reference is the pre-
ramp reference (parameter 1.03). The at speed indicator is active when the following is true:- ([1.03] - 3.06) < [3.02] < ([1.03] + 03.07)
3.09 = 1 absolute window mode. The at speed band is from the lower limit to the upper limit. The at speed indicator is active when the
following is true:-3.06 < [3.02] < 3.07.
The following diagram shows a generalised representation of the speed controller. The controller includes proportional (Kp) and integral (Ki)
feed-forward terms, and a differential (Kd) feedback term. The drive holds three sets of these gains and either set may be selected for use by
the speed controller with parameter 3.16.
3.16 = 1, gains Kp1, Ki1 and Kd2 are used
3.16 = 2, gains Kp2, Ki2 and Kd2 are used
3.16 = 3, gains Kp3, Ki3 and Kd3 are used
3.01
Final speed reference
ô
±Pr1.06
ð
rpm
RO
Bi
P
0.04
3.02
Speed feedback
ô
±Pr1.06
ð
rpm
RO
Bi
P
0.05
3.05
Zero-speed threshold
ô
0 ~ 200
ð
5
rpm
RW
Uni
3.06
At-speed lower limit
ô
±Pr1.06
ð
5
rpm
RW
Uni
3.07
At-speed upper limit
ô
±Pr1.06
ð
5
rpm
RW
Uni
3.08
Over-speed threshold
ô
0 ~ n
max
ð
rpm
RW
Uni
3.09
Absolute at-speed detect mode select
ô
0 ~ 1
ð
0
RW
Bit
3.10
Speed-loop proportional gain. Kp1
ô
0.0000 ~ 0.3000
ð
SLM
RW
Uni
0.13
3.11
Speed-loop integral gain. Ki1
ô
0.0000 ~ 30.000
ð
SLM
RW
Uni
0.14
3.12
Speed-loop derivative gain. Kd1
ô
0.0000 ~ 0.1000
ð
SLM
RW
Uni
0.15
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...