Menu 5 Parameters - Motor Control
Notes
The settings of parameter 5.34 are as follows:
0
kgm
2
1
kgcm
2
The settings of parameter 5.54 are as follows:
0
Ranges are as shown for 3.18 and 3.20
1
Ranges are divided by 10
Parameter
Range(
ô
)
Default(
ð
)
Type
5.05 {0.43}
DC-bus voltage
0 ~ 1000 V
RO
Uni
P
5.07 {0.19}
Motor - rated current
0 ~ FLC A
[SLM]
RO
Uni
5.08
Motor - rated speed
0 ~ 7500rpm
[SLM]
RO
Uni
5.09
Motor - rated voltage
0 ~ V
S
[SLM]
RO
Uni
5.11
Motor - number of poles
0 ~ 255
[SLM]
RO
Uni
5.12
Flux alignment test enable
0 ~ 1
0
RW
Bit
5.32
Motor torque-constant
0.00 ~ 500.00Nm/A
[SLM]
RO
Uni
5.33
Motor inertia
0.1 ~ 6000.0 kgcm
2
or
0.00001 ~ 0.6 kgm
2
[SLM]
RO
Uni
5.34 {0.11}
Inertia units selected
0 ~ 1
[SLM]
RO
Bit
5.52
Reserved for internal system purposes
5.53
Reserved for internal system purposes
5.54
Inertia range select
0 ~ 1
1
RW
Bit
FLC
Full-load current
(continuous-current rating of the drive)
V
S
AC supply voltage
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...