414L-M-V3
5.1.2 Multipoint Communication
Multipoint Communication is a system whereby a number of instruments can
be addressed over a dual twisted pair interface. Up to 32 instruments can
be connected to a common bus using the RS422 and RS485 interface as
shown below.
To convert the RS422 interface to an RS485 interface, the RS422 (-) Data In
Terminal must be connected to the RS422 (-) Data Out Terminal and the
RS422 (+) Data In Terminal must be connected to the RS422 (+) Data Out
Terminal.
These connections will convert the RS422 4 wire interface to the RS485 2
wire interface, as shown in figure 2.
Each instrument can be programmed with a unique address which is used by
the Master Controller (ie IBM/PC) to identify each instrument. The
Controller will send the address down the line and will alert the relevant
instrument.
Subsequent software protocol will control the flow of data between the
Controller and the Instrument.
Options
43
Figure 1 RS422 Interface
H o s t
C o m p u t e r
L o a d
120 ohms
T wisted Pair
L o a d
120 ohms
400 Series
Inst rument
400 Series
Inst rument
NB. Diagram refers to Version 3 Models Only
Version 3 models can be defined by having plug-off green terminals.
Содержание 414L
Страница 1: ...414L M V3 BATCH CONTROLLER MODEL 414L September 2013 ...
Страница 2: ...414L M V3 ...