414L-M-V3
4. TEMPERATURE
COMPENSATION
Temperature compensation gives the instrument the capability to correct
for changes in volume of the measured liquid with temperature. There
are three methods of compensation which can be selected.
1. Density correction for general liquids with known temperature
density characteristics. A five point temperature-density curve can
be programmed and the MASS flow calculated
2. Volume correction for general liquids using a thermal coefficient
of expansion with temperature. This method is useful for
correction to a base volume over relatively small changes in
temperature.
3. Correction for Petroleum Liquids to US and International standards
for a wide range of petroleums, to a base temperature of 60°F/15°C.
4. Correction for LPG to US and International standards, to a
base temperature of 60°F/15°C.
4.1 TEMPERATURE INPUT (RTD OR 4-20mA)
The Model 414L is available with either a PT100 Platinum RTD input or with
a 4-20mA input. The input option must be specified on ordering.
The temperature inputs are continually checked to ensure that they are
within the specified limits and an Input Error will be displayed as "Err 12" if
the 4-20mA input drops below 3.5mA or if the RTD resistance is outside the
valid resistance ranges.