Thick media
35
Optimized Thick Media Adjustment
(OTAC)
To scan thick media such as cardboard, foam board or Gator board the
height of the insertion slot should be increased by activating the Optimized
Thick Media Adjustment or OTAC for short.
OTAC should be used when scanning documents from 2mm to 16mm thick
(0.6”). Originals less than 2mm thick should be scanned with OTAC in its
lowest position (normal position).
Raising OTAC
Remove all of the paper return guides by lifting them off. Place them
away from the scanner
Lift the small lever underneath the larger button on the back of the
scanner lid nearest the keypad. The lid will lift to its maximum position
and increase the size of the insertion slot to 16mm. The yellow led will
light.
Insert the thick original center justified into the front of the scanner
keeping the leading edge square until it is under both lines of rollers
Lower OTAC
– see next page
Yellow led will light up when
OTAC is raised
LIFT the small lever upwards to raise OTAC
to its maximum height POSITION -16mm
LIFT