Fill and test information and procedure
|
|
|
1.
2.
3.
4.
5.12.1
Cover Collectors for this procedure to prevent pressure variation due to thermal activity in the
collectors.
The solar transfer fluid is of food grade and non toxic. However, care must be taken when
handling not to spill or accidentally consume. Always use the solar transfer fluid as specified
by Conergy and outlined above.
Every care must be taken to ensure that in installations where rain water is being collected from
the same roof, any spilt ST-5 solution is cleaned up immediately so that the ST-5 solution does
not contaminate the water in the rain water storage tank.
Remove the 100 kPa jacket relief valve from the tank socket. See Detail A for the location of
this valve.
Connect a ½” (12 mm) flexible hose to the fill tap located at the bottom
right side of the collector array. See Detail D for the location and the
photo to the right for detail.
Installation Instructions
With the aid of a funnel and hose connected to the fill tap, pour the
contents of the heat transfer fluid container into the funnel (4.5 litres)
then add drinking grade water until the fluid flows from the 100 kPa
jacket relief valve socket in the tank. See drawing below for the
detail.
Close the fill tap and insert the pressure test block into the tank’s 100
kPa jacket relief valve socket. To the right is a photo of the pressure
test block.
Jacket relief valve
(Detail A)
Funnel
Hose
Fill tap
(Detail D)
Detail D - Fill tap
Pressure test block