18.
19.
20.
System diagrams and components
For closed circuit models insert the 100 kPa closed circuit pressure relief valve into the ½” tank
socket as shown in Detail A. Note this valve is not used on open circuit models.
Using the straps supplied with the Parts Kit place one into each side of the tank front foot as
shown in Detail A. back leg so that they are over a rafter then screw fix in place to the rafter to
secure the tank in place. Take the straps under the tank and screw fix to the roof rafter.
Finally take the tank clamp and bolt it to the tank strap behind the tank so that the tank clamp
secures the tank to the tank strap. To complete the security screw fix the 2 tank clamps to the
tank using the 2 self drilling screws provided.
Flat Roof Installations
For flat roof installations a special mounting frame is required (For more information see Annex at
end of manual) Once the frame is mounted please follow the installation as outlined above.
Model TS300/4/O/XX/X/F20LC
5.7.1
5.8.1
5.8
*
Installation Instructions
*
Represents all AES and tank options.