![Conductix-Wampfler MultiLine 0835 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966061.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 61 of 81
Requirement:
DANGER!
Risk of injury due to entrapment!
There is a risk of being trapped by moving parts when the system is in operation. Moving parts
include, e.g. the shuttle and the current connectors fitted to it.
→
Do not enter the system's danger zone during operation
→
Always
disconnect the conductor rail system from the power supply
according to the 5 safety
rules and
secure it against being switched back
on before working on the conductor rail system.
For the 5 safety rules, see section 2.6
→
Wear close fitting working clothes
In order to observe the
most important safety measures
, the
appropriate operating conditions
specified in section 3.3.1 and
the following sections have to be observed.
DANGER!
Risk of injuries from falling conductor rails!
The following and similar substances can cause the conductor rails' holders to fail and cause the
conductor rail to fall down if they are kept near the conductor rail system:
Food that contains and from which aromatic compounds evaporate
Coating compounds and varnishes
Separating agents or coolants and lubricants
→
Do not store any of the above or similar substances near the conductor rails.
DANGER!
Do not energize the conductor rail!
The conductor rail must not be energized under the following conditions:
If the conductor rail is very dirty
If the conductor rail becomes wet
When live components are exposed (insulation profile or the insulation of the connecting cable
are damaged)
If the hanger clamp or insulation profile fail
If the power rail falls down and contacts a conductive material
→
Secure the electric system according to regulations
→
Install the conductor rail as described in the mounting instrcution
→
Take environmental conditions into account, perform regular checks, maintain and clean as detailed
in the instructions
→
The conductor rail must be regularly inspected and, if necessary, repaired.