Required protective equipment:
DANGER!
Risk of injury through crushing and impacts!
There is a risk of crushing skin and limbs from:
Current collector (spring force) during installation, deinstallation and maintenance
Falling conductor rail system components if they have not been properly installed or if operated in
inappropriate operating conditions (e.g. environment that contains solvents)
Moving parts when the system is in operation
→
Do not enter the system's danger zone during operation
→
Installation work must only be carried out by trained personnel
→
When working on the conductor rail system, protective footwear, protective gloves and protective
headgear must be worn
→
When exchanging carbon brushes, observe the separate instructions on this topic. See section 12.3
→
The conductor rail system must only be installed in locations with appropriate operating conditions.
See section 3.3.1
Required protective equipment:
DANGER!
Risk of injury from cuts and cutting!
The ends of the power rails can have sharp edges, especially if they were cut to size at the
construction site and have not been deburred.
→
Wear protective gloves and protective footwear.
→
During installation: Carefully deburr the insulation profile and the power rail after they have been cut
to size
→
During disassembly: Cut, dismantled conductor rails must be handled carefully and properly stored
(container or transport box)
→
Look out for sharp edges near the installation surface and avoid contact