![Conductix-Wampfler MultiLine 0835 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966010.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 10 of 81
2.4
Intended use
This product is designed and built only for the intended use described here.
WARNING!
Danger from improper use!
Any application that deviates from or goes beyond the intended use of the devices can result in
hazardous situations.
→
The specifications in this mounting instruction must be strictly complied with
→
Do not use the system in any way that does not conform to its intended use!
→
Observe the information on improper use in section 2.4.1
We do not accept any liability for damage arising from improper use.
The operator bears sole liability for all damage that result from improper use.
Intended use
The conductor rail system MultiLine 0835 is an electric power supply system for track-guided mobile consumers operated in indoor
spaces in the warehouse area not accessible to the public.
One of its typical applications is, for example, to supply power to shuttles inside a warehouse with horizontal storage racks.
The following technical requirements must always be strictly observed during installation:
The consumer's max. permissible travel speed is 300 m/min.
The conductor rail must
only be fitted horizontally.
CAUTION!
To fit the conductor rail vertically, there are a number of extra points that need to be taken into
consideration and doing so is only possible using special components.
The conductor rail system must only be fitted and operated using either steel
or
copper materials, but on no account a mixture
of steel and copper components.
Max. permissible installation height above ground/platform without safety gear: 3 m
Conductor rails installed higher than 3 m above ground have to be fitted with safety gear to prevent them from falling down.
Max. permissible system length: 150 m
The conductor rail system must not be exposed to splashing water.
Electrotechnical operating conditions
The electrical system has to be protected with fuses in compliance with local guidelines.
2.4.1
Improper use
Improper use
in particularly include the following types of use:
Operating the system outside the specified operating conditions (see section 3.3).
Exceeding the max. permissible travel speed.
Installing the conductor rail system with the opening for the current collector's access facing upwards.
Installing the conductor rail system at an angle.
Installing the system higher than 3 m above ground/platform without safety gear.
Installation in area accessible to the public.
Creating a conductor rail that is more than 150 m long.