Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 25 of 81
Fig. 6: Conductor rail 0835
Conductor rail 0835
The conductor rail is designed for transmitting energy. Every conductor rail
contains two conductor bars that are protected by an insulation profile.
All conductor rails have a standard length of 4 m. Conductix-Wampfler can
also supply shorter conductor rails of 0.5 m - 3.90 m on request.
Variants:
Copper or steel
2 x phase (standard) or 1 x phase, 1 x PE (protective earth)
DANGER!
In a worst case scenario, dismounting the connectors can cause a fire!
The connectors cannot be removed. Using force to remove a connector will damage the connector
and means that it can no longer be used because it will have become deformed, which means that it
will no longer be possible to guarantee that it will function properly.
→
Connectors must only be installed level, i.e. within the system and to the installation surface.
→
The connectors have to be made of the same material as the conductor bar.
→
The connection must not be bent or twisted.
Fig. 7: Current collector 0815
Current collector 0815
The current collector supplies the track-guided mobile consumer with the
required energy.