4
Description and mode of operation
4.1
Brief description
MultiLine 0835 is a conductor rail system that can be used to supply e.g. a shuttle (in a shuttle storage system) or similar mobile
consumers in other kind of applications with energy. The system is variable in length.
The conductor rail system MultiLine 0835 comprises:
Conductor rail components:
End segment with power feed (first section)
Conductor rail
End segment
Connectors
Hanger clamps
The hanger clamps are used to attach the conductor rails to a straight and smooth installation surface provided by the customer.
The installation surface generally comprises a steel profile. The conductor rails are connected to one another with the aid of
connectors, which ensure a low ohmic resistance and that the rails are securely connected.
The power feed at the top end of the conductor rail is used to supply the rail with electrical energy that the shuttle (or a different
kind of mobile consumer) can continuously access with the aid of a current collector.
4.2
Description of assemblies
Fig. 4: Hanger clamp 0835 with expanding rivet
Hanger clamp 0835 (universal model)
Hanger clamp 0835 is designed to be fitted with two expanding rivets to
the installation surface provided by the customer.
Hanger clamps 0835 are designed to hold the conductor rails and end
segments which are clipped into them.
Special hanger clamp models are available upon request.
Fig. 5: End segment 0835
End segment 0835
The end segments are fitted at the top and bottom end of the
conductor rail.
The end segment fitted at the top end contains an end cap bar to which
the conductor rail is fastened. This is why an end cap bar is only fitted at
the top end. This end segment also contains the power feed.
Variants:
Copper or steel
For connection cross-sections of 1.5 – 2.5 mm² or 4 – 6 mm²
2 x phase (standard) or 1 x phase, 1 x PE (protective earth)