![Conductix-Wampfler MultiLine 0835 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966050.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 50 of 81
5.
Cutting the rail sections in front of the end segment to size.
CAUTION!
The rail sections have to be at least 300 mm long!
See section 6.2.5 for information on adjusting the rails' length.
→
Determine the length of the rail sections or rail
section to be fitted, see section 6.2.5
→
Align the conductor bars and insulation profile to
be flush with one another at one end.
NOTE!
The conductor rail expands when the temperature
rises. Please provide ≥ 200 mm of free space at the
end.
→
The conductor bar must be protruding 15 mm
from the insulation profile at the other end.
Measure the required protruding section of rail
from the end of the conductor bar, mark and cut
to size. This means that, with a single cut, the
conductor bar will have been shortened to the
required size and have a shorter insulation
profile (extra space for expansion).
→
Carefully deburr the insulation profile and
conductor bar.
CAUTION!
If the conductor bar has not or not been
properly deburred, the sliding contact will wear
very heavily at this point.
→
Fit the right rail section with the connector and
connector cap.
Fig. 40: Cut the conductor rail to size
Use the QR code (“click“ or “scan“), to watch our animation
Cutting the Conductor Rail
.
Insulation profile
Conductor bar