3
Technical specifications
3.1
Electrical
Rated current
max. 32 A at 100 % DC (DC = duty cycle)
Nominal voltage
without protective earth (PE)
max. 48 V AC/DC
with protective earth (PE)
max. 500 V AC
Number of pins
2
Assignment
2 phases or 1 phase, PE
Cross sections for connecting cables
1.5 – 2.5 mm² or 4 – 6 mm²
Conductor material
Copper or steel
Protection class
IP 2X
3.2
Mechanical
Max. travel speed
300 m/min
Direction of travel
Back and forth (reversing)
Gap between pins
14 mm
3.2.1
Length
Max. length of the installed conductor rail
150 m*
Power rails
max. 4000 mm (standard),
500 to 3900 mm available on request
Min. permissible power rail length
300 mm
End segment with power feed (first section)
750 mm
End segment (end section)
750 mm
Longitudinally acting section of the connector*
2.5 mm + 1 mm per side