Fill Cup
Release the two tabs and remove the cover on the fill cup.
Use a soft-bristled brush (not wire brush) to remove any scale
buildup inside the fill cup.
Install the cover on the fill cup.
Drain Cup
Use a soft-bristled brush (not wire brush) to carefully remove
any scale buildup inside the drain cup.
Wash the drain cup with lukewarm soap solution, and rinse
thoroughly with tap water.
6.5
Resetting Cylinder
WARNING!
Risk of damage to equipment and property!
DO NOT reset the cylinder in the control software unless the steam cylinder has been
replaced.
Reset the cylinder in the control software as follows after replacing the steam cylinder(s):
1. Select the
<Menu>
button on the Home screen, then enter the password to login. Refer to
.
2.
Select
Service > General Service tab > Cylinder A Reset
. A reset dialog appears prompts you to
confirm the cylinder reset.
Note:
On units with dual steam cylinders, individually reset the appropri
-
ate maintenance counter – A, B, or both for the cylinder(s) replaced.
3. Select the
<Yes>
button on the confirmation screen. The Cylinder Status and the Cylinder Spent
status message are reset.
Select the
<No>
button at any time to abort the reset.
Содержание Nortec EL-Series
Страница 56: ...56 Operator Interface 2582954_D_EN_1811_Nortec EL_OM Nortec EL This page intentionally left blank...
Страница 74: ...74 Maintenance 2582954_D_EN_1811_Nortec EL_OM Nortec EL This page intentionally left blank...
Страница 84: ...84 Fault Isolation 2582954_D_EN_1811_Nortec EL_OM Nortec EL This page intentionally left blank...
Страница 88: ...88 Wiring Diagrams 2582954_D_EN_1811_Nortec EL_OM Nortec EL This page intentionally left blank...
Страница 93: ...Notes...
Страница 94: ......