1
7.3
Removing and installing parts for maintenance
7.3.1
Removal and installation of the steam cylinder
1. Use a screwdriver to undo the two screws fixing the front panel to the unit, then remove the
front panel.
2.
Units with steam hose connector in housing top
: release the two hose clamps on the rubber
sleeve using a screwdriver, then detach the rubber sleeve from the connection in the unit cover
and from the steam outlet connection of the steam cylinder.
Units without steam hose connector in housing top (not shown):
release the hose clamp
on the steam hose using a screwdriver, then detach the steam hose from the steam outlet con-
nection of the steam cylinder.
1
2
3
4
3. Remove all plugs from the electrodes and from the level sensor.
. Loosen the two screws of the steam cylinder fixing device by a few turns, then push the fixing
device upwards until it comes loose and remove it.