6.6.4.6
Cylinder settings
Cylinder
Cyl. Number :644
Cyl. Line :Dispos
Esc
Set
Select “
Cylinder
” in the settings menu, then press the
<Set>
key.
The cylinder settings appear. Press the
< >
and
< >
keys in order to
select the individual settings and press the
<Set>
key to call up the
modification dialogue for the selected setting.
Description of the cylinder settings
–
Cyl. Line
:
Selecting the cylinder type.
Factory setting:
Dispos
Options:
Dispos
(Disposable cylinder A..)
Clean
(Cleanable cylinder D..)
–
Cyl. Number
:
Selecting the cylinder number
Factory setting:
according the installed cylinder
Options:
342
,
343
,
363
,
444
,
464
,
654
,
644
,
664
,
674
–
Max.Heating
:
Setting the maximum heating time for the steam generator. As soon as
the maximum heating time is reached, the steam production is interrupted
and the drying phase begins (if the fan is activated). After the drying phase
the light is switched off automatically.
Factory setting:
2 h
Setting range:
1 ... 24 h
–
Max.Door Open
: Setting the maximum time the door of the steam bath cabin can be open,
before the steam production is interrupted.
Factory setting:
2 min
Setting range:
1 ... 30 min
6.6.4.4
Setting the date
Select “
Date
” in the settings menu, then press the
<Set>
key. In the upcom-
ing modification dialogue set the actual date (format: “dd.mm.yy”).
6.6.4.5
Setting the time
Select “
Time
” in the settings menu, then press the
<Set>
key. In the
upcoming modification dialogue set the actual time (format: “hh.mm”).
Settings
Time :12:00
Cylinder :Set
Power Limit :100%
Date :05.05.08
GFCI-Mode :Aus
Esc
Set
Settings
Date :05.05.08
Time :12:00
Cylinder :Set
BathSetting :Set
Power Limit :100%
Esc
Set
Settings
BathSetting :Set
Date :05.05.08
Time :12:00
Language :English
Cylinder :Set
Esc
Set