6-38
I
Troubleshooting
Removing the Pump
WARNING: Electrical Shock and Hot Surface Hazard
Before attempting maintenance of any kind on the Thermolator, you must stop the
unit; disconnect and lockout the main power supply; and allow the unit to cool to
100° F {38° C}.
1
Disconnect and lockout the main power.
2
Shut off the cooling water in feed.
3
Drain the unit of all fluid.
Remove the drain plug
at the rear of the unit.
4
Remove the top and side panels of the
Thermolator.
5
Remove the pump assembly bolts.
Use a 9/16-inch
open-end box wrench to remove the bolts holding
the pump to the pump casing. The bolt in the rear
will require a 9/16-inch socket wrench.
6
Remove the center brace that runs from the top
rear to the front of the Thermolator.
7
Lift the pump assembly straight up to remove.
The pump can now be replaced
or disassembled for repair. The center brace detail needs to be removed on selection
pumps removal.
8
Reverse the steps to reassemble the unit.
NOTE:
Before restarting, close all drain openings using
sealant on the threads and reprime the pump. Do not
start until the pump is completely filled with water.
Cooling Valve
and
From Process
connection
in this area
To Process
connection
in this area
Cooling water out
Cooling water in
DIRECT INJECTION
This configuration is
used for 48 kW and ¾
valves and up.