Maintenance
I
5-9
5
Maintenance
Removing the Pump Motor and Seal
(3 Hp, 50Hz and 5 to 10 Hp, any frequency units)
The following procedure can be used on all models with 5 to 10 hp pump motors for
disassembly:
1
Remove eight (8) pump casing bolts using a 9/16-inch wrench.
2
Remove motor and adapter from casing.
3
Inspect pump casing to adapter o-ring for damage.
If appropriate obtain replace-
ment part number 267204-0265-02.
4
Remove impeller bolt and washer using a 9/16-inch deep socket.
The bolt is
secured in place with a high performance thread locker. A significant amount of
torque will be required to break it free. The impeller may be clamped on the smallest
diameter round section behind the witness line of the casing interface only. Do not
damage the outside surface where the close clearance between the casing and impel-
ler exists.
Tools Required
r
9/16-inch wrench
r
Flat-blade screwdriver
r
9/16-inch deep socket
Time Required
20 Minutes
Motor
Motor Bolts
Casing
Impeller Bolt
O-Ring
Loc-Tite
Impeller Washer
Impeller
Casing Bolts
Mechanical Seal
Shaft Sleeve
Motor Adapter
Shaft Key
Contact Conair
Parts and Service
Phone: 800-458-1960
From outside of the
United States,
Call: 814 437 6861
(Continued)