MCDD-100 MetaCarrier Detection Device
Revision 3
Appendix A
MN-MCDD100
A–2
A.2
Scenario 1: Marginal Interference
Item
Description
A
“Interfering” 256 ksps Data Carrier
B
“Desired” 3.5 Msps Data Carrier
Figure A-1. Scenario 1 (Marginal Interference)
Figure A-1 shows a marginal interference scenario where a 256 ksps Data Carrier is interfering
with a 3.5 Msps Data Carrier.
In this situation, the energy of the interfering carrier is not significant. As shown, the 256 ksps
carrier does not have enough energy to completely interfere with the 3.5 Msps carrier. In most
cases, a carrier as small as this would not be detectable, and the only discernable problem
would be where the Forward Error Correction (FEC) does not compensate for the reduction in
Es/No due to the minor interference.
When both carriers have Carrier ID technology enabled, the MCxD-100 may be instructed to
look in the spectrum below the composite envelope of the 3.5 Msps carrier to determine if
Carrier IDs are present. Optimally, only a single carrier would be present, but in such
interference conditions, multiple Carrier IDs may be found.
Once an interfering carrier is found, the uplinking station may be contacted and a request made
to disable the identified transmission service.
Содержание MetaCarrier MCDD-100
Страница 8: ...MCDD 100 MetaCarrier Detection Device Revision 3 Table of Contents MN MCDD100 viii BLANK PAGE ...
Страница 30: ...MCDD 100 MetaCarrier Detection Device Revision 3 Installation MN MCDD100 2 6 Notes ...
Страница 40: ...MCDD 100 MetaCarrier Detection Device Revision 3 Rear Panel Connectors and Pinouts MN MCDD100 3 10 Notes ...
Страница 60: ...MCDD 100 MetaCarrier Detection Device Revision 3 Serial based Remote Product Management MN MCDD100 5 10 Notes ...
Страница 86: ...MCDD 100 MetaCarrier Detection Device Revision 3 Appendix A MN MCDD100 A 8 Notes ...
Страница 87: ......
Страница 88: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...