MCDD-100 MetaCarrier Detection Device
Revision 3
Serial-based Remote Product Management
MN-MCDD100
5–4
5.2.2
Packet Structure
The exchange of information is transmitted, Controller-to-Target and Target-to-Controller, in ‘packets’. Each packet contains a finite
number of bytes consisting of printable ASCII characters, excluding ASCII code 127 (DELETE).
In this context, the Carriage Return and Line Feed characters are considered printable. With one exception, all messages from Controller-
to-Target require a response – this will be either to return data that has been requested by the Controller, or to acknowledge reception of an
instruction to change the configuration of the Target.
Controller-to-Target (Issued Command or Query)
Start of Packet
Target Address
Address Delimiter
Instruction Code
Code Qualifier
Optional Arguments
End of Packet
<
ASCII code 60
(1 character)
0000 (default)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
= or ?
ASCII codes 61 or 63
(1 character)
(n characters)
Carriage Return
ASCII code 13
(1 character)
Packet Example:
<0000/IPA=010.006.030.001/24 [cr]
Target-to-Controller (Response to Command or Query)
Start of Packet
Target Address
Address Delimiter
Instruction Code
Code Qualifier
Optional Arguments
End of Packet
>
ASCII code 62
(1 character)
0000 (default)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
= or ?
ASCII codes 61 or 63
(1 character)
(n characters)
Carriage Return
ASCII code 13
(1 character)
Packet Example:
>0000/IPA=010.006.030.001/24 [cr][lf]
Detailed description of the packet components follow.
Содержание MetaCarrier MCDD-100
Страница 8: ...MCDD 100 MetaCarrier Detection Device Revision 3 Table of Contents MN MCDD100 viii BLANK PAGE ...
Страница 30: ...MCDD 100 MetaCarrier Detection Device Revision 3 Installation MN MCDD100 2 6 Notes ...
Страница 40: ...MCDD 100 MetaCarrier Detection Device Revision 3 Rear Panel Connectors and Pinouts MN MCDD100 3 10 Notes ...
Страница 60: ...MCDD 100 MetaCarrier Detection Device Revision 3 Serial based Remote Product Management MN MCDD100 5 10 Notes ...
Страница 86: ...MCDD 100 MetaCarrier Detection Device Revision 3 Appendix A MN MCDD100 A 8 Notes ...
Страница 87: ......
Страница 88: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...