MCDD-100 MetaCarrier Detection Device
Revision 3
Serial-based Remote Product Management
MN-MCDD100
5–6
5.2.2.5 Instruction Code Qualifier
This is a single character that further qualifies the preceding instruction code. Code Qualifiers obey the following rules:
From Controller-to-Target
, the only permitted characters are:
Character
Definition
=
(ASCII code 61)
This character is used as the Assignment Operator (AO). It establishes that the Instruction Code that precedes it is to
be used as a command to assign or configure operation. The instruction set that follows serves to assign the Target’s
new parameter setting or operational value.
Example: In a message from Controller-to-Target, IPA=aaa.bbb.ccc.ddd/yy means “set the IP Address and network
prefix for the Management | FE port to aaa.bbb.ccc.ddd/yy”
?
(ASCII code 63)
This character is used as the Query Operator (QO). It establishes that the Instruction Code that precedes it is to be used
as a query that returns the Target’s current configured parameter setting or operational value.
Example: From Controller-to-Target, IPA? means “what’s the current Management | FE port’s IP Address and network
prefix?”
From Target-to-Controller
, the only permitted characters are:
Character
Definition
=
(ASCII code 61)
This character is used in two ways:
a.
If the Controller sends a query to the Target – for example, IPG? (meaning “what’s the Management | FE port’s current
IP Gateway Address?”) – the Target responds with IPG= aaa.bbb.ccc.ddd, the value for that queried parameter.
b.
If the Controller sends an instruction to set a parameter to a particular value, and the value sent is valid, the Target
acknowledges the message and responds with IPG= (with no message arguments).
?
(ASCII code 63)
If the Controller sends an instruction to set a parameter to a particular value, and the value sent is not valid, the Target then
acknowledges the message and responds with, for example, SRC? (with no message arguments). This indicates that there
was an error in the message sent by the Controller.
Содержание MetaCarrier MCDD-100
Страница 8: ...MCDD 100 MetaCarrier Detection Device Revision 3 Table of Contents MN MCDD100 viii BLANK PAGE ...
Страница 30: ...MCDD 100 MetaCarrier Detection Device Revision 3 Installation MN MCDD100 2 6 Notes ...
Страница 40: ...MCDD 100 MetaCarrier Detection Device Revision 3 Rear Panel Connectors and Pinouts MN MCDD100 3 10 Notes ...
Страница 60: ...MCDD 100 MetaCarrier Detection Device Revision 3 Serial based Remote Product Management MN MCDD100 5 10 Notes ...
Страница 86: ...MCDD 100 MetaCarrier Detection Device Revision 3 Appendix A MN MCDD100 A 8 Notes ...
Страница 87: ......
Страница 88: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...