MCDD-100 MetaCarrier Detection Device
Revision 3
Rear Panel Connectors and Pinouts
MN-MCDD100
3–8
3.5.2
Alternating Current (AC) Power Interface (Standard)
Figure 3-5. MCDD-100 AC Power Interface
3.5.2.1 AC Operation (Standard) – Applying Power
Figure 3-6. Applying AC Power
To apply AC power to the MCDD-100:
•
First, plug the provided AC power cord female end into the unit.
•
Then, plug the AC power cord male end into the user-supplied power source.
•
Finally, switch the unit ON.
Feature
Description
1
On / Off Switch
2
Press-fit Fuse Holder
3
IEC Three-prong Connector
AC Power Specifications
Input Power
40W maximum, 20W typical
Input Voltage
100V to 240V AC, +6%/-10%, autosensing
(Total absolute max. range is 90V to 254V AC)
Connector Type
IEC
Fuse Protection
Line and neutral fusing :
(2X) 120/240VAC T2A 5x20mm slow-blow type fuses