MCDD-100 MetaCarrier Detection Device
Revision 3
Serial-based Remote Product Management
MN-MCDD100
5–7
Character
Definition
!
(ASCII code 33)
If the Controller sends an instruction code that the Target does not recognize, the Target responds by echoing the invalid
instruction, followed by !
Example: SRC!
*
(ASCII code 42)
If the Controller sends the command to set a parameter to a particular value, and the value sent is valid BUT the router will
not permit that particular parameter to be changed at present, the Target acknowledges the message and responds with,
for example, IPG* (with message arguments).
#
(ASCII code 35)
If the Controller sends a correctly formatted command, BUT the unit is not in Remote Mode, it does not allow
reconfiguration and responds, for example, with IPG#.
5.2.2.6 Optional Message Arguments
Arguments are not required for all messages. Arguments are ASCII codes for the characters ‘0’ to ‘9’ (ASCII codes 48 to 57), period ‘.’
(ASCII code 46), and comma ‘,’ (ASCII code 44).
5.2.2.7 End of Packet
Controller-to-Target: This is the ‘Carriage Return’ ([CR]) character (ASCII code 13).
Target-to-Controller: This is the two-character sequence ‘Carriage Return’, ‘Line Feed’ ([cr][lf]) (ASCII codes 13 and 10). Both indicate
the valid termination of a packet.
Содержание MetaCarrier MCDD-100
Страница 8: ...MCDD 100 MetaCarrier Detection Device Revision 3 Table of Contents MN MCDD100 viii BLANK PAGE ...
Страница 30: ...MCDD 100 MetaCarrier Detection Device Revision 3 Installation MN MCDD100 2 6 Notes ...
Страница 40: ...MCDD 100 MetaCarrier Detection Device Revision 3 Rear Panel Connectors and Pinouts MN MCDD100 3 10 Notes ...
Страница 60: ...MCDD 100 MetaCarrier Detection Device Revision 3 Serial based Remote Product Management MN MCDD100 5 10 Notes ...
Страница 86: ...MCDD 100 MetaCarrier Detection Device Revision 3 Appendix A MN MCDD100 A 8 Notes ...
Страница 87: ......
Страница 88: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...