Appendix C. MAINTENANCE
C.1
Overview
Chapter 4. ETHERNET INTERFACE OPERATION Sect. 4.5.4.6 Status | Trending
Graphs
Figure C-1. Comtech EF Data LPOD Outdoor Amplifiers / BUCs
The fans used by CEFD’s LPOD family of Outdoor Amplifiers / BUCs (Figure C-1) are designed
for long life, even in harsh environments. Still, they are mechanical devices, subject to wear, and
may need replacement after several years.
In most environments, CEFD recommends clearing the heat sinks of dust and debris
approximately once per year to ensure optimal fan life. This appendix outlines the procedures for
uninstalling the LPOD PD 1, PS 1.5, or PS 2 fan shroud, inspecting and cleaning the heat sinks,
and then re-installing the fan shroud.
Use the temperature trending data, available from the LPOD HTTP Interface ‘
Status | Trending
Graphs
’ page (
) as a guide to determine if more or less frequent preventative
maintenance is required.
Figure C-2. LPOD HTTP Interface ‘Status |Trending Graphs’ Page –
Temperature Graph Example
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...