Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Ethernet Interface Operation
4–31
MN-LPOD
4.5.4.5
Status | Statistics
This page shows all unread, stored statistics. Use it to configure how the LPOD handles and
shows statistics.
Figure 4-19. ‘Status | Statistics’ Page
Statistics
Click
[Refresh]
to see the latest page data.
Unread Stored Statistics: ###
This window shows the unread stored statistics log in sequential, date-stamped format. This page
shows a running tally of the number of unread stored statistics in the window header. The unit
shows the five oldest stored statistics. All events that are read from the log are removed from the
log automatically.
•
Select
Read Next Five Statistics
to cause the unit to return the oldest five unread stored
statistics that remain unread in the log. If fewer than five events are available for retrieval,
the remaining positions are padded with zeros. If there are no new events, the counter in
the header reads
000
.
•
Select
Initialize Statistics Pointer
to reset the internal pointer to allow queries to start at
the beginning of the statistics log.
Click
Submit
to update the window according to your selection.
Statistics Configuration
•
Statistics Interval
– Enter the interval at which statistics are logged. The interval is set in
minutes. Minimum resolution is 1 minute (001); maximum is 99 minutes (099). Default is
90 minutes (090).
•
Statistics Averaging
– Select
Enable
or
Disable
to set the
Statistics Averaging
function:
o
If
Enabled
, statistics data is averaged at a rate of once per second for 10
seconds.
o
If
Disabled
, burst values are logged instead of averaged values.
Click
[Submit]
to save the changes.
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...