Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–8
MN-LPOD
5.3.5.4
Instruction Code
This three-character alphabetic sequence is intended to be a mnemonic of its operational function. This aids in the readability of the
message, should you display it in its raw ASCII form. For example, “GAC” means “Global Amplifier Configuration”; “IPA” means “IP
Address”, etc. Both upper case and lower case alphabetic characters may be used (A-Z
and
a-z, ASCII codes 65-90
and
97-122).
5.3.5.5
Instruction Code Qualifier
This single character further qualifies the preceding instruction code.
Instruction Code Qualifiers obey specific rules.
5.3.5.5.1
Controller-to-Target Rules
From Controller-to-Target, the permitted qualifiers are = or ? (ASCII codes 61 or 63):
= (ASCII code 61)
This qualifier is the Assignment Operator (AO). It means that the parameter defined by the preceding byte should be set to the value of the
argument(s) that follow it. For example: MUT=1 means “set the Mute function to Enabled”.
? (ASCII code 63)
This qualifier is the Query Operator (QO). It means that the Target should return the value of the parameter(s) defined by the preceding
byte. For example: SWR? means “return the firmwares installed in the Active and Standby images”.
5.3.5.5.2
Target-to-Controller Rules
From Target-to-Controller, the Target transmits the symbol =, ?, !, *, or # (ASCII codes 61, 63, 33, 42, or 35) to the Controller:
= (ASCII code 61)
“=” displays in two ways:
•
If the Controller sends a command to set a parameter’s value, and the value is valid, the Target accepts the command by replying
with no message arguments. For example: >0001/MUT={CR}{LF}
•
If the Controller sends a query to a Target, the Target responds with the configured setting. For example, the query MUT? means
“is Muting enabled or disabled?”); the Target responds with >0001/MUT=x{CR}{LF} (where ‘x’ represents the configured state – ‘1’
being ‘enabled’ and ‘0’ being ‘disabled’).
? (ASCII code 63)
“?” displays when the Controller sends a command to set a parameter’s value, and the value is not valid. The Target rejects the message
by echoing the valid instruction, followed by this character. For example: >0001/MUT=?{CR}{LF}
! (ASCII code 33)
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...