Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–17
MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command
Query
Response to
Command
Response
to Query
Concise
Maintenance
Status
N/A
CMS?
95 bytes
Query only.
Returns the Maintenance status of the unit, response is semicolon-delimited, in
the form
aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;
ooo.o;ppp.p;qqq.q;rrr.r;sss.s;ttt.t where:
aaa.a=P24V1
bbb.b=P24V2
ccc.c=LNBVT (SEE NOTE 2)
ddd.d=P13VT
eee.e=P10V1
fff.f=A10V1
ggg.g=A10V2 (SEE NOTE 2)
hhh.h=P7V8T
iii.i=P5V8T
jjj.j=P2V5T
kkk.k=P1V2T
lll.l=N5V8T
mmm.m=FANR1 (SEE NOTE 2)
nnn.n=FANR2 (SEE NOTE 2)
ooo.o=BUCVT (SEE NOTE 2)
ppp.p=FWPWR
qqq.q=REFVT (SEE NOTE 2)
rrr.r=LNBCS (SEE NOTE 2)
sss.s=ATEMP
ttt.t=OTEMP (SEE NOTE 2)
NOTES:
1)
This is the concise version of the RMS command.
2)
ccc.c, ggg.g, mmm.m, nnn.n, ooo.o, qqq.q, rrr.r, and ttt.t will appear if the
appropriate model/options have been selected/installed. Otherwise, the
unused fields will display XXXXX.
EXAMPLE: <1/CMS?{CR}
>0001/CMS=aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m
;nnn.n;ooo.o;ppp.p;qqq.q; rrr.r;sss.s;ttt.t{CR}{LF}
CMS=
CMS=x….x
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...