Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–18
MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command
Query
Response to
Command
Response
to Query
Clear Statistics
Log
CSL=
N/A
1 byte
Command only.
Clears the statistics log entries in the form x, where x=1.
EXAMPLE: <0001/CSL=1{CR}
CSL=
CSL?
CSL*
CSL=
Clear Trending
Data
CTD=
N/A
1 byte
Command only.
Clears the trending data in the form x, where:
x=1
EXAMPLE: <0001/CTD=1{cr}
CTD=
CTD?
CTD*
CTD=
Concise Utility
Status*
N/A
CUS?
15 bytes
Query only.
Returns the Maintenance status of the unit, in the form aaaa;bbbbb;ccc, response
is semicolon-delimited, where:
aaaa=Remote Unit Address
bbbbb=Remote Baud Rate
ccc=Reference oscillator tuning voltage DAC value (present only if a reference
oscillator is installed)
EXAMPLE: <0001/CUS?{CR}
>0001/CUS=aaaa;bbbbb;ccc{CR}{LF}
CUS=
CUS=x….x
LNB Current
Window Enable
CWE=
CWE?
1 bytes
Command or Query.
Sets or returns the LNB current window alarm in the form x, where:
0=Disabled (DEFAULT)
1=Enabled (SEE NOTE)
NOTE: If disabled, the LCW value will be retained, but unused.
COMMAND EXAMPLE: <0001/CWE=0{CR}
CWE =
CWE?
CWE *
CWE =x
Set RTC Date
(by Month)*
DAT=
DAT?
6 bytes
Command or Query.
Sets or returns the Real-Time-Clock date in the form mmddyy, where:
mm=month of the year (01 to 12)
dd=day of the month (01 to 31)
yy=year (00 to 96) (2000 to 2096)
COMMAND EXAMPLE (date=April 25, 2016): <0001/DAT=042516{CR}
DAT=
DAT?
DAT*
DAT=mmd
dyy
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...