Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–16
MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command
Query
Response to
Command
Response
to Query
Concise RF
Power FET
Current Status
N/A
CFS?
Length varies
depending on
the number of
installed FETs
Query only.
Returns the power values of installed FETs, comma-delimited, in concise format.
NOTE: This is the condensed version of the RFS query.
EXAMPLE: <0001/CFS?{CR}
>0001/CFS=xxx,xxx,x.x,x.x,……….,x.x,{CR}{LF}
CFS=
CFS=x;…..
x
Circuit
Identification
CID=
CID?
48 bytes
Command or Query.
Sets or returns the user-defined label for the unit or station.
NOTE: The 48-character string is entered as one line, but it is read back from the
unit as two 24-byte lines of information.
Default Setting: ------CID MESSAGE-------
------------------------
COMMAND EXAMPLE: <0001/CID= Station #001--SSPA #01--{CR}
>0001/CID={CR}{LF}
QUERY EXAMPLE: <0001/CID?{CR}
>0001/CID={CR}
Station #001{CR}
--SSPA #01--{CR}{LF}
CID=
CID?
CID*
CID=x;…x
Calibrate LNB
Current
CLC=
CLC?
none
Command or Query.
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in
the form xxx.x.
Default value: 000.0
NOTES:
1)
This command returns a mode error if the LNB current source output has
not been enabled first (see LCS command).
2)
The LNB current alarm point is then determined by the calibrated LNB
reference point, and the LNB current window setting (see LCW command).
3)
The CLC query returns the value that was stored during the LNB current
calibration.
COMMAND EXAMPLE: <1/CLC=xxx.x{CR} (where xxx.x is the calibrated LNB
current value in mA)
QUERY EXAMPLE: <1/CLC?{CR}
>0001/CLC=xxx.x{CR}{LF}
CLC=
CLC?
CLC*
CLC=xxx.x
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...