Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Appendix A
A–7
MN-LPOD
The available operational settings for the Online Unit or Offline Unit serial remote commands are
as follows:
•
AMP=0 (the Rx power amplifier is turned OFF), or 1 (the Rx power amplifier is turned
ON)
•
MUT=0 (disabled, i.e., the Tx is NOT MUTED), or 1 (enabled, i.e., the Tx is MUTED – no
data is transmitted). Note that, in the Online Unit, the Tx Mute setting (MUT) drives that
unit’s LNB Bias Tee setting (SBT) – if MUT=0, then SBT=1; if MUT=1, then SBT=0.
•
AUX=0 (disabled, meaning that the Auxiliary Mute Mode is turned OFF, or NOT MUTED),
or 1 (enabled, i.e., the Auxiliary Mute Mode is turned ON, or MUTED)
•
SBT=0 (LNB Bias Tee in
Off State
, i.e., MUTED – no data is received), or 1 (LNB Bias
Tee is in
Through State
, i.e., NOT MUTED). Note that, in the Online Unit, the LNB Bias
Tee setting is driven by that unit’s Tx Mute setting (MUT) – If MUT=0, then SBT=1; if
MUT=1, then SBT=0.
•
LCS=0 (the LNB Current Source is DISABLED – no voltage transmitted), or, if so
equipped, 1-4 (where the selected LNB Current Source is 1=18V 22 kHz Disabled;
2=18V 22 kHz Enabled; 3=13V 22 kHz Disabled; or 4=13V 22 kHz Enabled).
For the Offline Unit tabulation:
The Offline Unit monitors the Online Unit control settings and
updates its settings every few seconds. As tabulated, “FOLLOW” means that this Offline Mute
control setting “follows” the Online Unit’s corresponding Offline Mute control. However, when an
Offline Unit control setting is listed as either “0” (disabled/OFF) or “1” (enabled/ON), this means
the Offline Mute selection “forces” this value and does not follow the Online Unit’s configuration.
A.2.2.1
Applicable Serial-Based Redundancy Commands and Queries
These serial remote commands and queries apply to redundancy operations:
Remote
Command
Meaning
Functional Description
RED
Redundancy
Online/Offline
Reports the appropriate unit’s online/offline status. Also used to force a
unit to go active (online).
ESW
Enable Switch Mode
Puts the unit into redundancy or standalone (manual) mode.
AFR
Auto Fault Recovery
Sets the latching state of faults. Either they will latch to the faulted state
or they will recover automatically.
AOF
Attenuation Offset
Individual attenuation command, used to adjust out small differences in
power levels of different amplifier.
Содержание LPOD PS 1
Страница 18: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Preface vi MN LPOD BLANK PAGE...
Страница 30: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Introduction 1 12 MN LPOD BLANK PAGE...
Страница 120: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Ethernet Interface Operation 4 38 MN LPOD BLANK PAGE...
Страница 130: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Serial Interface Operation 5 10 MN LPOD BLANK PAGE...
Страница 172: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 10 MN LPOD BLANK PAGE...
Страница 199: ...Low Power Outdoor LPOD Amplifier Block Up Converter BUC Revision 15 Appendix A A 37 MN LPOD...
Страница 237: ......
Страница 238: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...