CRS-311 1:1 Redundancy Switch
Revision 7
Cables and Connections
MN/CRS311.IOM
3–24
3.3.5.3 Multi-Port Ethernet Router Mode M&C Using the Network
Processor (NP) Interface Module
Referring
to
Figure
3
‐
15
:
If
the
multi
‐
port
Network
Processor
(NP)
Interface
Module
is
installed
for
use
in
Multi
‐
Port
Ethernet
Router
Mode
(see
Sect.
3.3.6.3
),
you
must
only
connect
to
any
one
of
the
NP
Interface
Module’s
four
Ethernet
ports
on
the
Redundant
and
Traffic
modems.
The
“J5
Ethernet”
port
is
not
used
with
this
configuration
.
You
can
have
a
single
‐
point
connection
for
both
Ethernet
M&C
and
Ethernet
Data
via
use
of
user
‐
provided
CAT5
cables
and
a
user
‐
provided
Layer
2
Ethernet
switch.
Because
“Port
1”
on
the
TMI/RMI
incorporates
a
Gigabit
Ethernet
switch,
it
is
important
to
use
this
port
for
the
Ethernet
M&C
connection.
3.3.5.4 Multi-Port Ethernet BPM Mode M&C Using the Network Processor
(NP) Interface Module
Referring
to
Figure
3
‐
16:
If
the
multi
‐
port
Network
Processor
(NP)
Interface
Module
is
installed
for
use
in
Multi
‐
Port
Ethernet
BPM
(Bridge
Point
‐
to
‐
Multipoint)
Mode
(see
Sect.
3.3.6.4
),
you
can
have
a
single
‐
point
connection
for
both
Ethernet
M&C
and
Ethernet
Data
via
use
of
user
‐
provided
CAT5
cables
and
a
user
‐
provided
Layer
2
Ethernet
switch.
Because
“Port
1”
on
the
TMI/RMI
incorporates
a
Gigabit
Ethernet
switch,
it
is
important
to
use
this
port
for
the
Ethernet
M&C
connection.
Содержание CRS-311
Страница 12: ...CRS 311 1 1 Redundancy Switch Revision 7 Table of Contents MN CRS311 IOM xii This page is intentionally blank...
Страница 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Страница 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Страница 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Страница 108: ...CRS 311 1 1 Redundancy Switch Revision 7 Modem RMI TMI and Switch Configuration MN CRS311 IOM 4 20 Notes...
Страница 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Страница 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Страница 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Страница 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Страница 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...