CRS-311 1:1 Redundancy Switch
Revision 7
Serial-based Remote Product Management
MN/CRS311.IOM
6–6
Note
that,
regardless
of
the
Switch
remote
communications
being
configured
for
either
EIA
‐
232
or
EIA
‐
485
mode,
the
internal
link
between
the
Switch
and
the
modems
is
always
fixed
at
EIA
‐
232,
9600
baud,
8
‐
N
‐
1,
address
0.
The
Controller
sends
a
packet
with
the
address
of
a
Target
‐
the
destination
of
the
packet.
When
the
Target
responds,
the
address
used
is
the
same
address,
to
indicate
to
the
Controller
the
source
of
the
packet.
The
Controller
does
not
have
its
own
address.
6.2.4.3 Address Delimiter
This
is
the
“forward
slash”
character
'
/
'
(ASCII
code
47).
6.2.4.4 Instruction Code
This
three
‐
character
alphabetic
sequence
identifies
the
message
subject.
Wherever
possible,
each
instruction
code
is
named
to
serve
as
a
mnemonic
for
its
intended
operation
–
e.g.,
BKH
for
B
ac
K
up
H
oldoff
time,
or
SID
for
S
witch
ID
,
etc.
This
aids
in
the
readability
of
the
message,
should
it
be
displayed
in
its
raw
ASCII
form.
Only
upper
case
alphabetic
characters
may
be
used
(‘
A
’
to
‘
Z
’,
ASCII
codes
65
‐
90).
6.2.4.5 Instruction Code Qualifier
This
is
a
single
character
that
further
qualifies
the
preceding
instruction
code.
Code
Qualifiers
obey
the
following
rules:
1.
Controller
‐
to
‐
Target
,
the
only
permitted
characters
are:
Character
Definition
=
(ASCII code 61)
This character is used as the Assignment Operator (AO). It establishes that the Instruction Code that precedes it is to be used as a
command to assign or configure operation. The instruction set that follows serves to assign the Target’s new parameter setting or
operational value.
Example: In a message from Controller-to-Target, BKH=12 means “set the BacKup Holdoff time for 12 seconds.”
?
(ASCII code 63)
This character is used as the Query Operator (QO). It establishes that the Instruction Code that precedes it is to be used as a query
that returns the Target’s current configured parameter setting or operational value.
Example: From Controller-to-Target, BKH? means, “what is the BacKup Holdoff time?”
Содержание CRS-311
Страница 12: ...CRS 311 1 1 Redundancy Switch Revision 7 Table of Contents MN CRS311 IOM xii This page is intentionally blank...
Страница 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Страница 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Страница 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Страница 108: ...CRS 311 1 1 Redundancy Switch Revision 7 Modem RMI TMI and Switch Configuration MN CRS311 IOM 4 20 Notes...
Страница 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Страница 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Страница 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Страница 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Страница 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...