CRS-311 1:1 Redundancy Switch
Revision 7
Serial-based Remote Product Management
MN/CRS311.IOM
6–4
•
Status
queries
(no
commands)
are
fast
(typically
less
than
333
ms).
•
Configuration
changes
(commands)
take
longer
and
vary
by
modem
type.
•
Individual
command
responses
are
faster
than
those
to
global
commands
(MGC).
More
parameters
require
more
time.
A
pass
‐
through
command
is
passed
with
little
inspection
by
the
Switch;
remember
that
the
modem
being
addressed
may
be
at
the
distant
end
of
an
EDMAC
link!
Types
of
pass
‐
through
commands:
o
To
a
local
modem;
o
To
a
modem
at
the
distant
end
(EDMAC);
o
To
a
local
BUC
or
transceiver
connected
to
a
local
modem;
o
To
a
distant
end
BUC
or
transceiver
through
the
distant
end
modem.
6.2.4 Packet Structure
The
exchange
of
information
is
transmitted,
Controller
‐
to
‐
Target
and
Target
‐
to
‐
Controller,
in
‘
packets
’.
Each
packet
contains
a
finite
number
of
bytes
consisting
of
printable
ASCII
characters,
excluding
ASCII
code
127
(DELETE).
In
this
context,
the
Carriage
Return
and
Line
Feed
characters
are
considered
printable.
With
one
exception,
all
messages
from
Controller
‐
to
‐
Target
require
a
response
–
this
will
be
either
to
return
data
that
has
been
requested
by
the
Controller,
or
to
acknowledge
reception
of
an
instruction
to
change
the
configuration
of
the
Target.
Controller-to-Target (Issued Command or Query)
Start of Packet
Target Address
Address Delimiter
Instruction Code
Code Qualifier
Optional Arguments
End of Packet
<
ASCII code 60
(1 character)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
= or ?
ASCII codes 61 or 63
(1 character)
(n characters)
Carriage Return
ASCII code 13
(1 character)
Содержание CRS-311
Страница 12: ...CRS 311 1 1 Redundancy Switch Revision 7 Table of Contents MN CRS311 IOM xii This page is intentionally blank...
Страница 22: ...CRS 311 1 1 Redundancy Switch Revision 7 Preface MN CRS311 IOM xxii Notes...
Страница 48: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 2 Notes...
Страница 62: ...CRS 311 1 1 Redundancy Switch Revision 7 Cables and Connections MN CRS311 IOM 3 16 Notes...
Страница 108: ...CRS 311 1 1 Redundancy Switch Revision 7 Modem RMI TMI and Switch Configuration MN CRS311 IOM 4 20 Notes...
Страница 128: ...CRS 311 1 1 Redundancy Switch Revision 7 Front Panel Operation MN CRS311 IOM 5 20 Notes...
Страница 166: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix A MN CRS311 IOM A 24 Notes...
Страница 178: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix B MN CRS311 IOM B 12 Notes...
Страница 186: ...CRS 311 1 1 Redundancy Switch Revision 7 Appendix C MN CRS311 IOM C 8 Notes...
Страница 194: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...